Einschließungs-Wärmetauscher

Qualität Wärmetauscher für den Außenregal Fabrik

Wärmetauscher für den Außenregal

Top Mounted Outdoor Rack Enclosure Heat Exchanger , Industrial Air Heat Exchanger Quick Details: Place of Origin: Shenzhen, China (Mainland) Rated Heat Exchange Capacity: 120W/K Brand Name: ESTEL Rated Heating Capacity:300/500W (optional) Model: HE06-120SEH/T Input Voltage: DC48V Product Name: Heat Exchanger for Outdoor Cabinet Rated Input Current: 2.95A Certification: ISO9001, CE, 3C, FCC, TLC Rated Input Power: 142W Cover Material: galvanized steel Working Temperature: -20
Qualität Wärmerohr-Einschließungs-Wärmetauscher Fabrik

Wärmerohr-Einschließungs-Wärmetauscher

IP55 Waterproof Heat Pipe Heat Exchanger For Outdoor Communication Cabinets Quick Details: Place of Origin: Shenzhen, China (Mainland) Rated Heat Exchange Capacity: 80W/K Brand Name: ESTEL Rated Heating Capacity:300/500W (optional) Model: HE06-80SEH/01 Rated Input Voltage: DC48V Product Name: Outdoor Cabinet Heat Exchanger Rated Input Current: 2.0A Certification: ISO9001, CE, 3C, FCC, TLC Rated Input Power: 96W Cover Material: galvanized steel Working Temperature: -20°C ~ +55
Qualität Hochwirksamer Gleichstromwärmetauscher für Telekommunikationsschränke im Freien 120 WK Wärmekapazität Fabrik

Hochwirksamer Gleichstromwärmetauscher für Telekommunikationsschränke im Freien 120 WK Wärmekapazität

High Efficiency DC Heat Exchanger for Outdoor Telecom Cabinets 120WK Heat Capacity Product Description for High Efficiency DC Heat Exchanger The EX Series Heat Exchanger is a high-efficiency thermal control solution designed for outdoor cabinets. It is part of a professional line developed by Envicool for applications such as telecom, radio base stations, power supply cabinets, and various outdoor equipment. This series provides an optimal environment for sensitive equipment
Qualität 48VDC 325W/K Gehäusewärmetauscher mit RS485 Modbus RTU-Kommunikation Fabrik

48VDC 325W/K Gehäusewärmetauscher mit RS485 Modbus RTU-Kommunikation

48VDC 325W/K Enclosure Heat Exchanger RS485 Communication MODBUS RTU Protocol Heat Exchanger The HCZA-325-000-250 heat exchanger is a passive cooling solution designed for various enclosed spaces, ensuring efficient heat dissipation for electronic equipment. Key Features Passive Cooling Design: Utilizes a counterflow heat exchanger core where ambient air passes through one side of an aluminum plate and contaminated air passes on the other side. This design allows heat
Qualität 48VDC 150W/K Protokoll des Einschließungs-Wärmetauscher-RS485 der Kommunikations-MODBUS RTU Fabrik

48VDC 150W/K Protokoll des Einschließungs-Wärmetauscher-RS485 der Kommunikations-MODBUS RTU

48VDC 150W/K Enclosure Heat Exchanger RS485 Communication MODBUS RTU Protocol 1. Application This heat exchanger is mainly used for outdoor cabinet cooling. Also widely applied in small and medium sized telecom room, UPS room, outdoor base station room, outdoor advertising machine, bank ATM room etc. 2. Introduction Heat Pipe Heat Exchanger is a full automation temperature control product. It uses intelligent controller to control the whole system of the heat exchanger.
Qualität Einschließungs-Wärmetauscher Modbus DC48V IP55 intelligente Temperaturüberwachung Fabrik

Einschließungs-Wärmetauscher Modbus DC48V IP55 intelligente Temperaturüberwachung

DC48V IP55 Enclosure Heat Exchanger Modbus Intelligent Temperature Control DC48V IP55 150W/K LCD Display Heat Pipe Outdoor Cabinet Heat Exchanger Modbus Intelligent Temperature Control 1. Application of Cabinet Heat Exchanger This heat exchanger is mainly used for outdoor cabinet heat exchange. Also widely applied in small and medium sized telecom room, UPS room, outdoor base station room, outdoor advertising machine, bank ATM room etc. 2. Brief Heat Pipe Heat Exchanger is a
Qualität Kabinett-Wärmetauscher-Kommunikations-Basisstation HEXE IP55 AC220V Fabrik

Kabinett-Wärmetauscher-Kommunikations-Basisstation HEXE IP55 AC220V

IP55 AC220V Door Mounted 40W/K Cabinet Heat Exchanger Communications Base Station HEX 1. Product introduction of heat exchanger According to the indoor and outdoor temperature cycle, the unit selective operation of the heat exchanger, to ensure indoor cooling requirements under the premise of achieving the goal of energy-saving operation. Product Features: (1) Widely used in communications base stations, computer rooms, IDC data centers, container-type square cabins and other
Qualität Einschließungs-Wärmetauscher abkühlendes Embeded AC220V 80W/K, das IP55 R134A anbringt Fabrik

Einschließungs-Wärmetauscher abkühlendes Embeded AC220V 80W/K, das IP55 R134A anbringt

AC220V 80W/K Enclosure Heat Exchanger IP55 R134A Refrigerant Embeded Mounting 1. Key Instructions Fast man-machine interface operation, real-time temperature display, automatic and accurate temperature control; Working environment range: - 40 ~ + 55 ℃; It is specially designed for the cooling of communication cabinet and automation system. The installation mode is flexible and convenient; It has the characteristics of low noise, anti fouling and IP55 protection; Industrial
Qualität Tür angebrachte abkühlende Zustimmung R134A Wärmetauscher-48VDC 120W/K IP55 ISO9001 Fabrik

Tür angebrachte abkühlende Zustimmung R134A Wärmetauscher-48VDC 120W/K IP55 ISO9001

48VDC 120W/K Enclosure Heat Exchanger IP55 R134A Refrigerant Embeded Mounting 1.Key Parameters Type Parameters Dimensions(Without flange) H*W*D 960*405*226mm Dimensions(With flange) H*W*D 994*436*226mm Installation environment Outdoor Mounting method Door mounted Working temperature -40℃ -55 ℃ Input voltage 48VDC Cooling capacity L35/L35 120W/K Rated Refrigerating input power(L35/L35) 174W Rated Refrigerating current (L35/L35) 3.7A Internal airflow 950 m3/h IP grade IP 55